XL800 控制器 XCL8010A |
XCL8010A |
Excel 800 plant controller |
|
Panle I/O |
XF821A |
8 analog input module (Panel) |
XF822A |
8 analog output module (Panel) |
XFR822A |
8 analog output module with override (Panel) |
XF823A |
12 binary input module (Panel) |
XF824A |
6 relay output module (Panel) |
XFR824A |
6 relay output module with override (Panel) |
XFR825A |
Actuator output module with override (Panel) |
|
Lon I/O |
XFL821A |
8 analog input module (LON) |
XFL822A |
8 analog output module (LON) |
XFLR822A |
8 analog output module with override (LON) |
XFL823A |
12 binary input module (LON) |
XFL824A |
6 relay output module (LON) |
XFLR824A |
6 relay output module with override (LON) |
|
Terminal socket Model |
XS821-22 |
Terminal socket for analog input and output modules.The package includes 1 terminal socket, 1 connector bride and 1 swivel label. |
XS823 |
Terminal socket binary input modules.The package includes 1 terminal socket, 1 connector bride and 1 swivel label. |
XS824-25 |
Terminal socket relay output and floating output modules.The package includes 1 terminal socket, 1 connector bride, 1 cross connector and 1 swivel label. |
|
Accessary (Optional) |
XS812 |
Manual disconnector module for analog input, analog output and binary input. The manual disconnector is plugged between the terminal socket and the electronic module. It allows manual disconnection of individual signals. This is useful during start-up. |
XS812RO |
Manual disconnector module for relay output.The manual disconnector is plugged between the terminal socket and the electronic module. It allows manual disconnection of individual signals. This is useful during start-up. |
XS814 |
10 auxiliary terminal blocks. The auxiliary terminal block is used for distribution of signals. It includes 2 blocks with 7 terminals which are connected to each other. |
XS815 |
20 cross connectors (red in below figure) for connection of 6 relay commons.One cross connector is included in the terminal socket package. |
XS817 |
40 cross connectors (red in below figure) for connection of 3 relay commons (used if voltage on relay 1…3 is different to voltage on relay 4…5) |
XS816 |
10 bus bridges. One bus bridge is included in the terminal socket package. |
XAL10 |
10 swivel labels. The swivel label is used to attach the application specific label printed with CARE.One swivel label is included in the terminal socket package. |
XW882 |
XI582 cable for Excel 800 (a combination of XW586 and XW582 can be also used). |
XW885 |
Download cable for Excel 800 (a combination of XW586 and XW585 can be also used). |
XW884 |
Adapter cable to use XW882 and XW885 with an XL500 controller |
|